What should I do if the heating function of the high pressure steam sterilizer china fails
- Categories:high pressure steam sterilizer
- Author:
- Origin:
- Time of issue:2022-06-14
- Views:0
(Summary description)High pressure steam sterilizer china is a high-quality sterilization equipment in modern laboratories. All the instruments have touch buttons, and the operating language can be switched to Chinese, which is more convenient to use.
What should I do if the heating function of the high pressure steam sterilizer china fails
(Summary description)High pressure steam sterilizer china is a high-quality sterilization equipment in modern laboratories. All the instruments have touch buttons, and the operating language can be switched to Chinese, which is more convenient to use.
- Categories:high pressure steam sterilizer
- Author:
- Origin:
- Time of issue:2022-06-14
- Views:0
High pressure steam sterilizer china is a high-quality sterilization equipment in modern laboratories. All the instruments have touch buttons, and the operating language can be switched to Chinese, which is more convenient to use. The system has its own sterilization program, and can also write multiple sterilization programs according to actual needs, making the operation program simpler, and it is not necessary to manually adjust the time and temperature due to changes in the load.
Disinfection and sterilization are the most basic operating techniques in microbial experimental technology. Therefore, personnel engaged in drug production and inspection should understand the basic concepts of disinfection and sterilization, the relationship between the two, their respective application methods and their significance. Strictly implement relevant operating procedures, on the one hand to ensure the effect of production and inspection work, on the other hand to protect their own safety.
However, when the high pressure steam sterilizer china is in use, sometimes the heating function fails and the steam cannot be produced normally. When the high pressure steam sterilizer china is running, the heating indicator on the panel is on, but the temperature indicator does not rise, the high pressure steam sterilizer china has been maintained at room temperature, what should I do?
For this, you can turn on the high pressure steam sterilizer china side, and the panel display is normal, indicating that the 220V power supply enters the control circuit normally. Remove the wire connected to the heating tube, and use a multimeter to check the resistance of the heating tube. Generally, the resistance is between 8-15Ω. If the resistance is too large, it indicates that the heating tube is broken and needs to be replaced. Since the high pressure steam sterilizer china heating tube is burned out for a reason, no matter whether the high pressure steam sterilizer china heating tube is good or not, you should check the solid state relay of the high pressure steam sterilizer china that controls the heating tube. When the high pressure steam sterilizer china is powered on, the input voltage of the relay should be around 12V DC and the output voltage should be around 220V AC. If the input of the high pressure steam sterilizer china is normal and the output is abnormal, this relay must be replaced. If the input of the high pressure steam sterilizer china is abnormal, check the load output control part on the control circuit.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers