High pressure steam sterilizer is a device that uses saturated pressure steam to sterilize items quickly and reliably. It is suitable for medical and health, scientific research, agriculture and other units. Autoclave sterilizers are divided into portable autoclave sterilizers, vertical autoclave sterilizers, and horizontal autoclave sterilizers according to style and size. It can sterilize medical equipment, dressings, glassware, solution culture medium, etc.
Steps
1. First, take out the inner sterilization bucket, and then add an appropriate amount of water to the outer pot to make the water surface level with the triangular shelf.
2. Put it back into the sterilization bucket and load the items to be sterilized. Be careful not to pack too much, so as not to hinder the flow of steam and affect the sterilization effect.
3. Put the cap on, and insert the capped exhaust hose into the exhaust slot of the inner sterilization barrel. Tighten the opposite two bolts at the same time in a symmetrical manner, so that the bolts are tight and consistent, and do not leak air.
4. Turn on the power to heat, and at the same time open the vent valve to boil the water to remove the cold air from the pot. After the cold air is completely exhausted, close the exhaust valve and let the temperature in the pot gradually rise as the steam pressure increases. When the pressure in the pot rises to the required pressure, control the heat source and maintain the pressure for the required time.
5. When the time required for sterilization is up, cut off the power supply or turn off the gas, and let the temperature in the high pressure steam sterilizer drop naturally. When the pressure of the pressure gauge drops to 0, open the exhaust valve, loosen the bolt, open the cover, and take out the sterilizer. Bacterial items.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn