Table top steam sterilizer how to empty the air
- Categories:table top steam sterilizer
- Author:
- Origin:
- Time of issue:2022-05-31
- Views:0
(Summary description)In the airtight table top steam sterilizer, the steam cannot escape, and the pressure continues to rise, so that the boiling point of the water continues to increase, so the temperature in the pot also increases.
Table top steam sterilizer how to empty the air
(Summary description)In the airtight table top steam sterilizer, the steam cannot escape, and the pressure continues to rise, so that the boiling point of the water continues to increase, so the temperature in the pot also increases.
- Categories:table top steam sterilizer
- Author:
- Origin:
- Time of issue:2022-05-31
- Views:0
In the airtight table top steam sterilizer, the steam cannot escape, and the pressure continues to rise, so that the boiling point of the water continues to increase, so the temperature in the pot also increases. Under the pressure of 0.1MPa, the temperature in the pot reaches 121℃. At this steam temperature, a variety of bacteria and their highly heat-resistant spores can be quickly killed.
Only when the air in the table top steam sterilizer is completely removed, so that all the water vapor in the pot can be completely sterilized. There are several different methods of high-pressure sterilization and air release, but the purpose is to exhaust the air, make the temperature in the pot evenly, and ensure complete sterilization. The common method is to close the air release valve. After the power is turned on, when the pressure rises to 0.05MPa, open the air release valve and release the air. After the pointer of the pressure gauge returns to zero, close the air release valve. After closing the valve and then energizing, when the pressure gauge rises to 0.1MPa, start timing and maintain the pressure at 0.1-0.15MPa for 20 minutes.
After the pressure holding time is reached, the power supply can be cut off. When the pressure drops to 0.5MPa, the steam can be released slowly. Care should be taken not to reduce the pressure too fast, causing intense decompression boiling and overflowing the liquid in the table top steam sterilizer. . When the pressure drops to zero, the lid can be opened, the medium is taken out, and placed on the platform to wait for condensation. Do not deflate for a long time, causing changes in the composition of the medium, so that the medium cannot be tilted. Once placed for too long, the lid cannot be opened due to the negative pressure in the boiler. As long as the air release valve is opened, the atmospheric pressure is entered, and the internal and external pressures are balanced, and the lid can be easily opened.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn