(Summary description)Best table top steam sterilizer is a device that uses electric heating wire to heat water to generate steam and can maintain a certain pressure. It mainly consists of a sealable barrel, pressure gauge, exhaust valve, safety valve, heating wire, etc. It is an ideal equipment for disinfection and sterilization of medical equipment, dressings, glassware, solution culture medium, etc.
Problems that should be paid attention to in the daily use of Best table top steam sterilizer
(Summary description)Best table top steam sterilizer is a device that uses electric heating wire to heat water to generate steam and can maintain a certain pressure. It mainly consists of a sealable barrel, pressure gauge, exhaust valve, safety valve, heating wire, etc. It is an ideal equipment for disinfection and sterilization of medical equipment, dressings, glassware, solution culture medium, etc.
- Categories:table top steam sterilizer
- Author:
- Origin:
- Time of issue:2022-06-09
- Views:0
Best table top steam sterilizer is a device that uses electric heating wire to heat water to generate steam and can maintain a certain pressure. It mainly consists of a sealable barrel, pressure gauge, exhaust valve, safety valve, heating wire, etc. It is an ideal equipment for disinfection and sterilization of medical equipment, dressings, glassware, solution culture medium, etc.
Daily use precautions
1. Best table top steam sterilizer should be operated by trained and qualified personnel, and the whole sterilization process should be supervised by special personnel.
2. The automatic water level protection cannot be completely relied upon, and the water level should always be paid attention to to avoid burning out the electric heating tube.
3. When adding water manually. The power supply should be cut off first, the vent valve 3 should be opened to relieve pressure, and then the water inlet valve should be opened to add water. Do not open the water inlet valve when the interlayer is under pressure, and the vent valve should be open when adding water.
4. When the sterilization chamber is under pressure, the interlock handle cannot be lifted, and the door cannot be forced.
5. The steam should be released slowly after sterilizing the liquid. The door can only be opened when the liquid temperature drops below 700C. Best table top steam sterilizer prohibits opening the door immediately after sterilization.
6. During the sterilization process of Best table top steam sterilizer, if the power is cut off or the temperature is lower than the sterilization temperature due to other reasons, the timing should be restarted when the temperature reaches the sterilization temperature again.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn