(Summary description)In case of power failure or accident, immediately cut off the horizontal steam sterilizer in china power supply, and open the condensation control valve and drain valve at the same time, so that the steam in the interlayer and inner layer can be discharged in time, and the pressure gauge returns to "0".
Precautions for use of horizontal steam sterilizer in china
(Summary description)In case of power failure or accident, immediately cut off the horizontal steam sterilizer in china power supply, and open the condensation control valve and drain valve at the same time, so that the steam in the interlayer and inner layer can be discharged in time, and the pressure gauge returns to "0".
- Categories:horizontal steam sterilizer
- Author:
- Origin:
- Time of issue:2023-03-14
- Views:0
1. In case of power failure or accident, immediately cut off the horizontal steam sterilizer in china power supply, and open the condensation control valve and drain valve at the same time, so that the steam in the interlayer and inner layer can be discharged in time, and the pressure gauge returns to "0". And accidents should be marked on the sterilizer and dealt with in time.
2. Different types of items should not be sterilized at the same time. Such as dressings and solutions, rubber and instruments, etc. In order not to lose sight of the other and fail to achieve good results.
3. Electric heating requires three-phase power balance, otherwise it is easy to burn out the fuse or electric heating tube. At the same time, always observe the water level. If the water level is low, add water in time. Regularly remove the scale on the conductive posts.
4. The pressure gauge and safety valve should be checked regularly. If any fault or damage is found, it should be repaired or replaced in time. The handle of the safety valve should be lifted once or twice a week to keep it flexible. 5. The electrical connector should be checked frequently to prevent loosening. The equipment should be properly grounded to ensure safety.
6. The horizontal steam sterilizer in china should be kept clean and dry, especially when it is not in use temporarily, it should be wiped clean to avoid corrosion, and the rotating parts should be lubricated in time.
7. To avoid corrosion of stainless steel by chloride ions, pay attention to the chloride ion content in the water used shall not exceed 25ppm.
8. The horizontal steam sterilizer in china should be operated under good conditions and maintained regularly to ensure normal operation.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn