(Summary description)Take out the inner bucket, and then add an appropriate amount of water to the outer pot of the portable steam sterilizer. When the water surface is equal to the triangular shelf, it is enough.
Matters needing attention during the use of portable steam sterilizer
(Summary description)Take out the inner bucket, and then add an appropriate amount of water to the outer pot of the portable steam sterilizer. When the water surface is equal to the triangular shelf, it is enough.
- Categories:portable steam sterilizer
- Author:
- Origin:
- Time of issue:2022-10-27
- Views:0
Take out the inner bucket, and then add an appropriate amount of water to the outer pot of the portable steam sterilizer. When the water surface is equal to the triangular shelf, it is enough. I don't know if you noticed this when you poured water. It should be noted that neither the conical flask nor the mouth end of the test tube should be in contact with the barrel wall. This is because we do not want the condensed water to wet the paper at the mouth and penetrate the cotton plug.
Another point, capping, is a common operation in our operation of portable steam sterilizer, but during the operation, we often make mistakes, we must insert the exhaust hose on the cover into the exhaust slot of the inner barrel Inside. Then tighten the opposite two bolts at the same time in a two-by-two symmetrical manner, making sure not to leak air.
After the required time is completed, be sure to cut off the power supply or turn off the gas, and let the temperature in the portable steam sterilizer drop naturally. At this time, when the pressure of the pressure gauge drops to 0, open the exhaust valve, loosen the bolt, open the cover, and be careful. Remove the item. Of course, if you find that the pressure gauge has not dropped to 0, we must not open the exhaust valve, because as long as the exhaust valve is opened, the pressure in the pot will suddenly drop, so that the medium in the container will be flushed out due to the imbalance of internal and external pressure. The mouth of the flask, which will cause the cotton plug to contaminate the medium and contaminate the medium, then our operation will end in failure.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn