Jiangsu Dengguan Medical Device Co., Ltd

NEWS

Maintenance of high pressure steam sterilizers

(Summary description)High pressure steam sterilizer, also known as high pressure steam sterilizer, pressure steam sterilizer, can be divided into portable autoclave, vertical autoclave, desktop pressure steam sterilizer, large horizontal pressure steam sterilizer Mushroom pot.

Maintenance of high pressure steam sterilizers

(Summary description)High pressure steam sterilizer, also known as high pressure steam sterilizer, pressure steam sterilizer, can be divided into portable autoclave, vertical autoclave, desktop pressure steam sterilizer, large horizontal pressure steam sterilizer Mushroom pot.

Information

High pressure steam sterilizer, also known as high pressure steam sterilizer, pressure steam sterilizer, can be divided into portable autoclave, vertical autoclave, desktop pressure steam sterilizer, large horizontal pressure steam sterilizer Mushroom pot. A device that generates steam by heating water through an electric heating wire and can maintain a certain pressure. It mainly consists of a sealable barrel, pressure gauge, exhaust valve, safety valve, electric heating wire, etc.

high pressure steam sterilizer

High pressure steam sterilizer is suitable for medical and health undertakings, scientific research, agriculture and other units to sterilize medical equipment, dressings, glassware, solution culture medium, etc.

When using a pressure steam sterilizer, the following requirements should be strictly observed:

1. In order to ensure safe use, the power cord of the sterilizer should be well grounded.

2. The high pressure steam sterilizer should be placed in a suitable environment, should be ventilated and dry, and free of flammable and explosive materials.

3. Do not disassemble the safety valve, the lead seals and screws on the steam release valve, etc.

4. The items stacked in the sterilizer should not exceed 4/5 of the volume, otherwise there will be potential safety hazards.

5. When the sealing ring is attached with oil, it is easy to damage the colloid and cause air leakage, which should be avoided as much as possible.

6. Chemicals that cause explosion or sudden pressure increase in contact with the steam medium cannot be sterilized with a sterilizer.

7. When stacking sterilized items, it should be ensured that enough space is left, and the outlet holes of the safety valve and the steam release valve cannot be blocked, so as to ensure the smooth flow of air and ensure safety.

8. The liquid should be filled in a heat-resistant glass bottle for sterilization. The liquid should not exceed 3/4 of the bottle volume. The bottle mouth should not use perforated rubber or cork stoppers, but cotton yarn stoppers.

9. Do not put items of different types and different sterilization requirements together for sterilization.

10. After the sterilization is over, the steam cannot be released immediately, and the residual gas must be discharged after the pointer of the pressure gauge returns to zero.

11. The pressure gauge should be calibrated regularly and replaced in time if necessary.

12. Check the safety valve regularly, and replace it immediately when it fails.

13. Always check the sealing of the sealing ring and replace it in time.

14. After the high pressure steam sterilizer is used, the water in the container should be removed, and if there is scale on the container or electric heating tube, it should also be cleaned to prolong the life.

Keyword:

Scan the QR code to read on your phone

Relevant Information

The use of Dengguan steam sterilizer

The use of Dengguan steam sterilizer

The company's steam sterilizer is a safe and reliable sterilization equipment that adopts automatic program control, which is mainly composed of a shell, a sterilization chamber, a steam generator, a piping system, and a control system.
Everything You Need to Know About Portable Steam Sterilizers

Everything You Need to Know About Portable Steam Sterilizers

Discover the benefits and uses of portable steam sterilizers in the medical equipment industry. Find out how these devices can help you maintain a clean and safe environment for medical instruments.
Tips for Maintaining and Cleaning Your Air Mattress

Tips for Maintaining and Cleaning Your Air Mattress

Learn how to keep your air mattress in top condition with these helpful tips for cleaning and maintenance. From preventing leaks to removing stains, we've got you covered.
上一页
1
2
...
193

CONTACT US

Jiangsu Dengguan Medical Equipment Co., Ltd.

Tel:0086-519-82421222

Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags

Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd.  All Rights Reserved.  苏ICP备2021032787号     powered by: www.300.cn

Jiangsu Dengguan Medical Equipment Co., Ltd.

苏ICP备2021032787号

powered by: www.300.cn