(Summary description)The determination of the sterilization time of the dental autoclave is not fixed. The lower the sterilization temperature, the longer the sterilization time required; the higher the sterilization temperature, the shorter the sterilization time required; It will be counted from when the temperature in the sterilizer cabinet reaches the required sterilization temperature until the sterilization is completed.
How dental autoclave Determine Sterilization Time
(Summary description)The determination of the sterilization time of the dental autoclave is not fixed. The lower the sterilization temperature, the longer the sterilization time required; the higher the sterilization temperature, the shorter the sterilization time required; It will be counted from when the temperature in the sterilizer cabinet reaches the required sterilization temperature until the sterilization is completed.
- Categories:dental autoclave
- Author:
- Origin:
- Time of issue:2022-04-24
- Views:0
The concepts of disinfection and sterilization are different. Disinfection refers to killing or eliminating pathogenic microorganisms on the transmission medium, so that the number is reduced to the point where it can no longer cause human disease, that is, to achieve the purpose of harmless treatment, such as boiling, pasteurization, ultraviolet radiation, etc. Sterilization refers to not only killing and removing infectious pathogenic microorganisms, but also killing and removing all microorganisms, including non-pathogenic microorganisms, that is, no viable bacteria exist, such as: high pressure steam sterilization, hexane oxide sterilization Wait. The determination of the sterilization time of the dental autoclave is not fixed. The lower the sterilization temperature, the longer the sterilization time required; the higher the sterilization temperature, the shorter the sterilization time required; It will be counted from when the temperature in the sterilizer cabinet reaches the required sterilization temperature until the sterilization is completed.
Dental autoclave sterilization times include these 3 categories:
1. The penetration time is calculated from the time when the pot reaches the sterilization temperature, and the time when the most difficult part in the pot reaches this temperature;
2. Maintenance time, that is, the time required to kill microorganisms, generally expressed as the time required to kill Bacillus stearothermophilus spores;
3. Safety time, the additional time required to ensure the sterilization of the dental autoclave is exactly guaranteed. Generally, it is half of the heat death time, and its length depends on the disinfection items. Sterilization of thermally conductive metal equipment does not require a safe time. During the sterilization time, pay attention to the pressure gauge, and adjust the intake air volume to maintain the pressure at the sterilization time until the sterilization time. During the sterilization process, if the pressure and temperature drop, the temperature should be increased and the time should be re-timed.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn