Jiangsu Dengguan Medical Device Co., Ltd

NEWS

Heating of horizontal steam sterilizer china

(Summary description)The horizontal steam sterilizer china should be registered with the local special equipment supervision agency before installation and use

Heating of horizontal steam sterilizer china

(Summary description)The horizontal steam sterilizer china should be registered with the local special equipment supervision agency before installation and use

Information

The horizontal steam sterilizer china should be registered with the local special equipment supervision agency before installation and use, and the operators of the horizontal steam sterilizer china must receive special training, be familiar with the operating system, and strictly abide by the operating procedures during operation. The horizontal steam sterilizer china belongs to a kind of pressure vessel, and it is strictly forbidden to use it under excessive pressure. For the specific data of horizontal steam sterilizer china, please refer to the quality certificate of the equipment. Horizontal steam sterilizer china Before use, check whether all instruments are normal, whether the power supply is correct and good, the spare valve should be closed, the water must be added above the high water level before work, and the sterilization temperature and time should be set. Let's talk about the relevant content of its heating.

horizontal steam sterilizer china

Close the condensation control valve, turn the power switch to "on", the power indicator light is on, the water level indicator light is on, turn on the heating switch, the heating indicator light is on, indicating that the water tank has begun to heat up, and the steam generated enters the jacket.

When the water level of the water tank is lower than the specified water level, the heating power supply can be automatically cut off, the water level indicator light goes out, the alarm indicator light is on and a buzzer sounds. At this time, the power switch should be turned off, and water should be added when the steam pressure between layers is zero. After adding water, you can continue heating. When the jacket pressure exceeds the upper limit set by the jacket pressure gauge, the heating power supply is automatically cut off, and the heating indicator light goes out. In the future, the current will be turned on and off, and the pressure will automatically remain stable. When the jacket pressure exceeds the set pressure of the pressure controller, the heating indicator light goes out and the heating stops.

Keyword:

Scan the QR code to read on your phone

Relevant Information

The use of Dengguan steam sterilizer

The use of Dengguan steam sterilizer

The company's steam sterilizer is a safe and reliable sterilization equipment that adopts automatic program control, which is mainly composed of a shell, a sterilization chamber, a steam generator, a piping system, and a control system.
Everything You Need to Know About Portable Steam Sterilizers

Everything You Need to Know About Portable Steam Sterilizers

Discover the benefits and uses of portable steam sterilizers in the medical equipment industry. Find out how these devices can help you maintain a clean and safe environment for medical instruments.
Tips for Maintaining and Cleaning Your Air Mattress

Tips for Maintaining and Cleaning Your Air Mattress

Learn how to keep your air mattress in top condition with these helpful tips for cleaning and maintenance. From preventing leaks to removing stains, we've got you covered.
上一页
1
2
...
193

CONTACT US

Jiangsu Dengguan Medical Equipment Co., Ltd.

Tel:0086-519-82421222

Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags

Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd.  All Rights Reserved.  苏ICP备2021032787号     powered by: www.300.cn

Jiangsu Dengguan Medical Equipment Co., Ltd.

苏ICP备2021032787号

powered by: www.300.cn