Correct use of dental autoclave is the guarantee of safe production
- Categories:dental autoclave
- Author:
- Origin:
- Time of issue:2022-04-27
- Views:0
(Summary description)Dental autoclave is a device for moist heat sterilization of culture medium (culture material). It is advisable to use a small portable sterilizer or a medium-sized vertical sterilizer for the production of parent seeds. When making original seeds, cultivars or substitute clinker cultivation, a large horizontal sterilizer (sterilizer) can be used. Correct use of dental autoclave is the guarantee of safe production. Let's take a look at its usage and precautions below.
Correct use of dental autoclave is the guarantee of safe production
(Summary description)Dental autoclave is a device for moist heat sterilization of culture medium (culture material). It is advisable to use a small portable sterilizer or a medium-sized vertical sterilizer for the production of parent seeds. When making original seeds, cultivars or substitute clinker cultivation, a large horizontal sterilizer (sterilizer) can be used. Correct use of dental autoclave is the guarantee of safe production. Let's take a look at its usage and precautions below.
- Categories:dental autoclave
- Author:
- Origin:
- Time of issue:2022-04-27
- Views:0
Dental autoclave is a device for moist heat sterilization of culture medium (culture material). It is advisable to use a small portable sterilizer or a medium-sized vertical sterilizer for the production of parent seeds. When making original seeds, cultivars or substitute clinker cultivation, a large horizontal sterilizer (sterilizer) can be used. Correct use of dental autoclave is the guarantee of safe production. Let's take a look at its usage and precautions below.
1. Add water to the dental autoclave sterilizer except that some sterilizers are equipped with steam supply boilers, other sterilizers need to be added with appropriate amount of water, and then steam is generated from the water. To this end, adding water must pay attention to two points, _ is the water quality, and the second is the amount of water. The water quality is not only required to be clean, but also distilled water or deionized water should be used to avoid scale formation after long-term use, which will affect the normal use of the equipment. The amount of water should be added according to the requirements of the instructions, and it should not be too much or too little.
2. Loading capacity of dental autoclave sterilizer In order to facilitate the smooth circulation of steam in the sterilizer, the loading capacity of each time should be appropriate. It is generally recommended to leave a volume of 1/5N1/4, which is both economical and effective, especially for bagged culture materials, and a steam channel should be reserved so as not to affect the sterilization effect.
3. Exhaust heating, close the door of the sterilization pot, and start heating and heating. When the pressure in the pot reaches 0.04 MPa, the cold air in the pot needs to be exhausted, otherwise the pressure and temperature cannot rise synchronously, and the phenomenon of low temperature and high pressure will appear, which will affect the sterilization effect.
4. Dental autoclave sterilization conditions The sterilization conditions of the mother seed medium are: 121, 15 pounds force (0.11 MPa, 20 to 30 minutes; the sterilization conditions of the original seed and cultivated seed medium are: 126, 20 Pound force (0.14 MPa), 1.5 to 2 hours.
Scan the QR code to read on your phone
Relevant Information
The use of Dengguan steam sterilizer
Everything You Need to Know About Portable Steam Sterilizers
Tips for Maintaining and Cleaning Your Air Mattress
CONTACT US
Jiangsu Dengguan Medical Equipment Co., Ltd.
Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags
Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd. All Rights Reserved. 苏ICP备2021032787号 powered by: www.300.cn