(Summary description)In order to ensure safe use, the power cord of the pressure steam sterilizer should be well grounded, placed in a suitable environment, ventilated and dry, and free of inflammable and explosive materials.

The use of pressure steam sterilizer needs to pay attention to these matters

(Summary description)In order to ensure safe use, the power cord of the pressure steam sterilizer should be well grounded, placed in a suitable environment, ventilated and dry, and free of inflammable and explosive materials.

Information

In order to ensure safe use, the power cord of the pressure steam sterilizer should be well grounded, placed in a suitable environment, ventilated and dry, and free of inflammable and explosive materials.

Do not disassemble the safety valve, the lead seal and the screw on the steam release valve.

Items stacked in the sterilizer should not exceed 4/5 of the volume, otherwise there will be potential safety hazards.

When stacking sterilized items, it should be ensured that enough space is left, so as not to block the air outlet of the safety valve and the steam release valve, so as to ensure the smooth flow of air and ensure safety.

pressure steam sterilizer

Before use, check all circuits to confirm that the circuits are safe and normal; check the water volume in the pressure steam sterilizer water tank, and confirm that the water volume has not passed the spiral pipe.

Open the door to place the sterilized items, and close the closed door of the automatic high pressure steam sterilizer (note that the protruding iron sheet should press the travel switch when closing the door).

The liquid should be filled in a heat-resistant glass bottle for sterilization. The liquid should not exceed 3/4 of the bottle volume. It is not appropriate to use a punched rubber or cork stopper for the bottle mouth, but a cotton gauze stopper.

Do not put items of different types and different sterilization requirements together for sterilization.

After use, scrub the equipment cover and the sealing ring of the equipment to ensure that there is no oil and no dust.

Keyword:

Scan the QR code to read on your phone

Relevant Information

The use of Dengguan steam sterilizer

The use of Dengguan steam sterilizer

The company's steam sterilizer is a safe and reliable sterilization equipment that adopts automatic program control, which is mainly composed of a shell, a sterilization chamber, a steam generator, a piping system, and a control system.
What does the pressure steam sterilizer include

What does the pressure steam sterilizer include

According to the different discharge methods of cold air, pressure steam sterilizers are divided into two categories: down-exhaust pressure steam sterilizers and pre-vacuum pressure steam sterilizers.
Anti-bedsore mattresses in china can be maintained like this

Anti-bedsore mattresses in china can be maintained like this

Anti-bedsore mattresses in China can be inflated immediately after purchase, but it is best to use them 12 hours after the first inflation is completed 8 hours later. Because anti-bedsore mattresses in China need a cushioning process for the inner straps and seams, try not to inflate the new anti-bedsore mattresses in China 2 days before use.
上一页
1
2
...
58

CONTACT US

Jiangsu Dengguan Medical Equipment Co., Ltd.

Tel:0086-519-82421222

Address: No. 17, Danfeng West Road, Jintan District, Changzhou City, Jiangsu Province
SEO Tags

Webpage © Jiangsu Dengguan Medical Equipment Co., Ltd.  All Rights Reserved.  苏ICP备2021032787号     powered by: www.300.cn

Jiangsu Dengguan Medical Equipment Co., Ltd.

苏ICP备2021032787号

powered by: www.300.cn